ReadyPlanet.com
dot
Consumable for Chromatography
dot
dot
dot
bulletVICI Valco Cheminert
bulletVICI Jour
bulletSyringe and needle
bulletHPLC Columns
bulletDiluter and Dispenser
bulletPipettes and Pipetters
dot
Filtration Solution Products
dot
Filtration apparatus
bulletSPE Vacuum manifold
bulletSciChro Vacuum Pump
bulletLABVAK Vacuum pump
bulletVacuum Glass Filtration Apparatus
bulletStorage Bottle filtration set
bulletMembrane Filters
dot
Sample Preparation Products
dot
dot
Sample Concentrator Nitrogen Blow Down
dot
bulletSample Concentrator Nitrogen Blow Down




Safety Cap for HPLC Mobile Phase

 

  GL45 Safety Cap for HPLC Mobile Phase

 

Features:

1.    GL45 solvent bottle caps protect your laboratory environment. The system provides protection and secures laboratory work. The integrated PTFE membrane captures dust and other contaminants from the air.

2.    Ergonomic design allows easy and tool-free solvent changes, the freely rotating cap insert and screw-on fittings avoid twisting of the tube during container changes.

3.    For maximum efficiency, the time bar ( 6 months ) installed on the valve clearly indicates the usage of the valve and when the filter needs to be replaced.

 Benefits of solvent bottle caps:

1.     Reduce solvent volatilization, protect the health of experimenters, and save solvents.

2.    Filter particles in the air to prevent dust from contaminating reagents and further improve data quality.

3.     Each pipe has an independent sealing interface, which is neat, uniform and beautiful.

4.    The ergonomic design allows easy container changes without tools, while the freely rotating lid insert and finger-tight fittings also avoid twisting the tube during container changes.

5.    A time bar is mounted on the top of the cover, clearly indicating usage and when the cover needs to be replaced.

 NOTICE:

1.     When you first start using it, just press your finger on the time bar to start it;

2.    The time bar will gradually turn red after startup. When it turns completely red, it is time to replace the air valve, as shown in the figure below;

3.    We recommend replacing the air valve after 6 months of use under the following conditions: 1 ml/min, 5 days a week, 8 hours a day, laboratory temperature 20°C.

 



Ordering Information

Part No.

Descriptions

ราคา (บาท)***

250301

GL45 Safety Cap for HPLC Mobile phase + One way valve (ANW)

2,800

250302

One way air valve with time strip 6 month (ANW)

1,900

350303

GL45 Safety Cap for HPLC Mobile phase without one way valve (ANW)

900

250304

Time Strip 6 month

300

250305

Fitting 1/4-28 thread adapter for tubing OD 1/8”,

180

***ราคาไม่รวมภาษีมูลค่าเพิ่ม

 




HPLC Mobile phase solvent filtration

Solvent Filtration Set with 1000ml Flask Bottle
Solvent Filtration Set with 1000ml Duran Bottle
Membrane Filters
Vacuum pump
Safety Waste Cap
SS316 Stainless Steel Mobile Phase filter / helium sparger
Oil free Diaphragm Vacuum pump
SAIEISE Filtration apparatus 1000ml
Lachoi Vacuum pump
Syntware filtration apparatus